3,797 research outputs found

    Looking at the future of manufacturing metrology: roadmap document of the German VDI/VDE Society for Measurement and Automatic Control

    Get PDF
    "Faster, safer, more accurately and more flexibly'' is the title of the "manufacturing metrology roadmap'' issued by the VDI/VDE Society for Measurement and Automatic Control (<a href="http://www.vdi.de/gma"target="_blank">http://www.vdi.de/gma</a>). The document presents a view of the development of metrology for industrial production over the next ten years and was drawn up by a German group of experts from research and industry. The following paper summarizes the content of the roadmap and explains the individual concepts of "Faster, safer, more accurately and more flexibly'' with the aid of examples

    Development of optical diaphragm deflection sensors

    Get PDF
    The objective of this project was to develop high-temperature pressure sensors using non-metallic components and optical sensing methods. The sensors are to operate over a temperature range from room temperature approx. 20C to 540C, to respond to internal pressure up to 690 kPa, to respond to external pressure up to 690 kPa, and to withstand external overpressure of 2070 kPa. Project tasks include evaluating sensing techniques and sensor systems. These efforts include materials and sensing method selection, sensor design, sensor fabrication, and sensor testing. Sensors are tested as a function of temperature, pressure, overpressure, and vibration. The project results show that high-temperature pressure sensors based on glass components and optical sensing methods are feasible. The microbend optical diaphragm deflection sensor exhibits the required sensitivity and stability for use as a pressure sensor with temperature compensation. for the microbend sensor, the 95% confidence level deviation of input pressure from the pressure calculated from the overall temperature-compensated calibration equation is 3.7% of full scale. The limitations of the sensors evaluated are primarily due to the restricted temperature range of suitable commercially available optical fibers and the problems associated with glass-to-metal pressure sealing over the entire testing temperature range

    Incomplete quantum state estimation: a comprehensive study

    Full text link
    We present a detailed account of quantum state estimation by joint maximization of the likelihood and the entropy. After establishing the algorithms for both perfect and imperfect measurements, we apply the procedure to data from simulated and actual experiments. We demonstrate that the realistic situation of incomplete data from imperfect measurements can be handled successfully.Comment: 11 pages, 10 figure

    J004457+4123 (Sharov 21): not a remarkable nova in M31 but a background quasar with a spectacular UV flare

    Full text link
    We announce the discovery of a quasar behind the disk of M31, which was previously classified as a remarkable nova in our neighbour galaxy. The paper is primarily aimed at the outburst of J004457+4123 (Sharov 21), with the first part focussed on the optical spectroscopy and the improvement in the photometric database. Both the optical spectrum and the broad band spectral energy distribution of Sharov 21 are shown to be very similar to that of normal, radio-quiet type 1 quasars. We present photometric data covering more than a century and resulting in a long-term light curve that is densely sampled over the past five decades. The variability of the quasar is characterized by a ground state with typical fluctuation amplitudes of ~0.2 mag around B~20.5, superimposed by a singular flare of ~2 yr duration (observer frame) with the maximum at 1992.81 where the UV flux has increased by a factor of ~20. The total energy in the flare is at least three orders of magnitudes higher than the radiated energy of the most luminous supernovae, provided that it comes from an intrinsic process and the energy is radiated isotropically. The profile of the flare light curve appears to be in agreement with the standard predictions for a stellar tidal disruption event where a ~10 M_sun giant star was shredded in the tidal field of a ~2...5 10^8 M_sun black hole. The short fallback time derived from the light curve requires an ultra-close encounter where the pericentre of the stellar orbit is deep within the tidal disruption radius. Gravitational microlensing provides an alternative explanation, though the probability of such a high amplification event is very low.Comment: Accepted for publication in Astronomy and Astrophysics, 14 pages, 11 figure

    Information theoretic approach to single-particle and two-particle interference in multi-path interferometers

    Get PDF
    We propose entropic measures for the strength of single-particle and two-particle interference in interferometric experiments where each particle of a pair traverses a multi-path interferometer. Optimal single-particle interference excludes any two-particle interference, and vice versa. We report an inequality that states the compromises allowed by quantum mechanics in intermediate situations, and identify a class of two-particle states for which the upper bound is reached. Our approach is applicable to symmetric two-partite systems of any finite dimension.Comment: RevTex 4, 4 pages, 2 figure

    Statistics of dressed modes in a thermal state

    Full text link
    By a Wigner-function calculation, we evaluate the trace of a certain Gaussian operator arising in the theory of a boson system subject to both finite temperature and (weak) interaction. Thereby we rederive (and generalize) a recent result by Kocharovsky, Kocharovsky, and Scully [Phys. Rev. A, vol. 61, art. 053606 (2000)] in a way that is technically much simpler. One step uses a special case of the response of Wigner functions to linear transformations, and we demonstrate the general case by simple means. As an application we extract the counting statistics for each mode of the Bose gas.Comment: to appear in Optics Communications, 10 page

    Impact of intravitreal ranibizumab, aflibercept and bevacizumab on retinal ganglion cell and nerve fibre layer thickness in Neovascular age-related macular degeneration

    Get PDF
    Purpose: To compare the effects of monotherapy with intravitreal ranibizumab, aflibercept and bevacizumab on retinal ganglion cell layer (RGCL) and retinal nerve fibre layer (RNFL) in patients with naïve neovascular age-related macular degeneration (nAMD). Methods: This is a retrospective cohort study with three-groups comparison. 83 patients and 97 eyes on continuous monotherapy with an intravitreal anti-vascular endothelial growth factor (anti-VEGF) were followed for 24months and divided into three groups according to anti-VEGF (aflibercept: 25 eyes, ranibizumab: 34 eyes, bevacizumab: 38 eyes). Main outcome measures included: RGCL and RNFL thickness, best corrected visual acuity (BCVA), central macular thickness (CMT), macular volume (MV) and the presence of intraretinal fluids (IRF), subretinal fluids (SRF) and retinal pigment epithelial atrophy (RPE-atrophy). All outcome measures were recorded at the time of the first injection, 1 and 2years after treatment and compared longitudinally and between groups. Results: The mean age was 79±7years. The RGCL thickness, MV, CMT and the presence of IRF and SRF decreased significantly within all three medication groups (p<0.05 for all) with no significant difference between groups over the 2-year follow-up period (p>0.10 for all). The decrease in RNFL thickness was not significant within or between the groups after a 2-year follow-up (p>0.055 for all). RPE-atrophy increased significantly after 2 years in all three groups (p<0.028 for all) with no significant difference between groups at all three time points (p>0.307 for all). BCVA was comparable between the three groups over the 2-year follow-up period (p>0.22 for all). Conclusions: Monotherapy with intravitreal aflibercept, bevacizumab and ranibizumab was associated with comparable significant decreases in RGCL thickness, CMT, MV, IRF and SRF in naïve nAMD patients during the first 2 years of treatment. Furthermore, no significant differences either in BCVA or RNFL thickness were observed between the three intravitreal anti-VEFGs during the first 2 years of treatment
    corecore